Gasboard-3200L Biomethane Analyzer uses TDLAS, NDIR, and ECD sensors for precise, real-time measurement of CH4, H2S, CO2, and O2 in biomethane. Gasboard-3200L calculates calorific value automatically, making it ideal for biogas quality monitoring, process control, and grid injection.
Gasboard-3200L Biomethane Analyzer is a portable biogas analysis device developed using advanced TDLAS, NDIR, and ECD gas sensing technologies. It is specially designed for biomethane quality monitoring, enabling real-time and precise measurement of CH4, H2S, CO2, and O2. With ultra-low H₂S detection (0–20 ppm) and high-accuracy CH4 readings (better than 0.5% FS), it provides automatic calorific value calculation for use in biogas upgrading, process control, and grid injection.
This analyzer delivers fast results without sample preparation, offering a cost-effective alternative to gas chromatography (GC). Its compact and rugged design makes it ideal for on-site biomethane testing, combining portability, efficiency, and high precision in one device.
Highly selective TDLAS technology for accurate CH4 measurement (<0.5% FS)
Accurately measures hydrogen sulfide from 0–20 ppm, ideal for biomethane quality control
Rapid results, no sample preparation, outperforms GC efficiency
Minimizes consumables and maintenance, offering a reliable and economical solution
| Measurement Components | CH4, CO2, O2, H2S |
| Measurement Principle | TDLAS, NDIR, ECD |
| Measurement Range | CH4: 0-100%*; CO2: 0~100%; O2: 0~5%; H2S: 0~20ppm (can be customized) |
| Accuracy | CH4: ±0.5%F.S. (for CH4>60%); CO2: ±1%F.S.; O2/H2S: ±2%F.S. |
| Repeatability | 1%F.S. |
| Resolution | CH4/CO2/O2: 0.01%; H2S: 1ppm |
| Response Time (T90) | <30S |
| Power Supply | 100~240VAC, 50~60Hz (standard) |
| Inlet Flow Rate | 0.7~1.2L/min |
| Inlet Gas Pressure | 2~50kPa |
| Sampling Gas Condition | No dust, no vapor, no tar |
| Dimension (L*W*H) | 412*152*294 (mm) |
| Weight | 9kg |
| Communication | RS-485/RS-232 |
| Power Supply | Built-in rechargeable lithium battery External 12.6V charger |
| Display | LCD |
| Function | Built-in sampling pump; with the ability to freely switch between heat value units of Kcal/m³ and Mj/m³; It also features self-diagnosis functionality, allowing online checking of sensor status. |
* Note: CH4 concentration should be higher than 60%
Contact Cubic Sensor to Explore Innovative Methane Gas Sensing Solutions!
inquiry@gassensor.com.cn
+86-27-81628827
Fenghuang No.3 Road, Fenghuang Industrial Park, Eastlake Hi-tech Development Zone, Wuhan, 430205, China